⿎ Installation Space
For the appropriate air cooling, provide space around the device as shown in the following figure.
Notice
• Ensure the minimum bent radius of each cable.
• Please install not to bar the flow of air cooling.
• Installing near a heating element could be over ambient temperature and cause malfunction of the product.
• When setting more than one laser marker, install them so that a space of 300 mm or more is given between the heads of
each marker. Not doing so may cause malfunction. It might cause the malfunction with the laser marker.
66
200 mm
150 mm
150 mm
ME-LP400V-OP-6