⿎ Lot
When inputting lot character, the lot is marked with the condition set previously.
Set the expiry date function "4-9-3 Lot" (P.166), and set the character.
Refer to "3-3-3 Mark Lot No." (P.98).
Notice
• The following items, Date, Lot, and Expire Date are marked based on the internal clock integrated in the laser marker.
The internal clock might be deviated caused by the error of the internal parts or degree of the battery drain. Therefore,
be sure to check the time of the internal clock before the operation without fail.
Reference
• By using "TIME HOLD IN" signal of the I/O connector pin No. 23, the functional characters such as date/time and lot
do not update and the laser marker marks the time and date at the point when the input was turned ON. For the TIME
HOLD IN function, refer to the "External control manual".
Description
1
Lot (Lot No.):
Select the No. of the lot condition set in the function screen.
Lot No.: 0 to 3
Setting Range
Common Lot No.: 4 to 7
Character strings to represent the functional characters of lot
%SFT:n
: Lot character
Item
Displayed characters
n
Represents the lot function number.
0 to 3
4 to 7
1
Description
Lot No. 0 to Lot No. 3
Common Lot No. 4 to Common Lot No. 7