Panasonic LP-V Series Operation And Maintenance Manual page 190

Laser marker
Hide thumbs Also See for LP-V Series:
Table of Contents

Advertisement

⿎ Code Type and Code Data
Code Type
CODE39
ITF
CODE128
NW-7
EAN/UPC
GS1 DataBar
GS1 DataBar Limited
GS1 DataBar
Expanded
2D side of composite
code
QR code (Model 1)
QR code (Model 2)
Micro QR
DataMatrix (ECC200)
GS1 DataMatrix
Reference
[CODE128]
• Inputting the control code "FNC1" to the head of the barcode data, CODE128 changes to UCC/EAN128(GS1-128).
• In the case that "FNC1" is set at the head in CODE128 and 13-digit characters are inputted after "01", a check digit is
added at 14th digit automatically.
• The start code A, B, C for CODE128 is selected automatically depending on the content of the data.
[ITF]
• Add "0" at the head of data if the number of characters inputted including the check characters is odd.
[GS1 DataBar]
• RSS code and GS1 DataBar code are the same code.
• The supported standard of GS1 DataBar Limited is 2011 version and 2006 version of ISO/IEC 24724.
• For GS1 DataBar, GS1 DataBar Limited and those composite codes, input 13-figure numbers as the code data. In those
human readable text, "01" as AI in the head of the text and the check digit (modulus10/weight 3-1) in the end of the text
are indicated automatically.
190
Available characters
0 to 9, A to Z, space, symbols - + / $ % .
0 to 9
• Characters within ASCII Code 00 (HEX) to 7F (HEX): 0 to 9,
A to Z, a to z, symbols and control codes
• Function character (FNC1)
0 to 9, symbols - $ : / . +
0 to 9
The bar code to be generated is determined based on the
number of character inputted as shown below:
• EAN-13: Input by 12 figures without check digit.
• EAN-8: Input by 7 figures without check digit.
• UPC-A: Input by 11 figures without check digit.
• UPC-E: Input by 6 figures without check digit.
0 to 9
0 to 9, A to Z, a to z, symbols (! " % & ' ( ) * + , - . / : ; < = > ? _ ),
space, function character (FNC1)
• Number mode (1 byte character): 0 to 9
• Alphanumerical mode (1 byte character): 0 to 9, A to Z,
space, $ % * + - . / :
• Binary mode: Characters within ASCII Code 00 (HEX) to
7F (HEX), consisting of 0 to 9, A to Z, a to z, symbols and
control codes.
• Kanji mode (2 byte character): JIS level-1 and JIS level-2
within JIS code 2121 to 7426 (HEX)
• Binary mode: Characters within ASCII Code 00 (HEX) to
7F (HEX), consisting of 0 to 9, A to Z, a to z, symbols and
control codes.
• Kanji mode :JIS level-1 and JIS level-2 within JIS code 2121
to 7426 (HEX)
0 to 9, A to Z, a to z, symbols (! " % & ' ( ) * + , - . / : ; < = > ? _),
function character (FNC1)
ME-LP400V-OP-6
number of characters
Max. 60 characters
6, 7, 11, or 12 digits
13 digits
Max. 60 characters
CC-A: Max. 56 characters
CC-B: Max. 255 characters
CC-C: Max. 255 characters
Max. 255 characters

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Lp-400 seriesLp-w series

Table of Contents