5
Source (Count Source) :
Target for timing of counting up and counting down. The count-up or count-down is started at the timing of count
source end. The count source can be switched by pressing button.
Setting Range
6
Reset at Data Update:
With checking on this function, the counter value is reset at the internal clock becomes "0:00".
Reference
• When the date changes during the Time Hold function is effective, the counter value is reset at the timing of releasing
Time Hold (the time hold input is OFF).
• The counter reset at update cannot apply to the marking to flying object.
7
RESET:
Returns current value to initial value by pressing [RESET].
236
TRIG (Trigger)
Counts up or counts down by trigger input.
Counter 0
Counter 1
Counts up or counts down when counter 0, 1, 2 or 3 ends.
Counter 2
Counter 3
Counter 4
Counter 5
Counts up or counts down when common counter 4, 5, 6 or 7 ends.
Counter 6
Counter 7