(2) Equidistant Marking
Marking is repeated every time the line moves with the interval set in equidistant marking.
Equidistant marking is performed while the marking trigger is turned to ON.
Reference
• Equidistant marking on the flying object cannot be used in combination with rank marking, external offset, and serial
data marking function.
When the encoder is not used
(Encoder signal: invalid)
3
2
4
Description
1
Interval (Marking Interval)
Inputs the moving distance of the line for marking start.
Setting Range
2
Line Speed
Inputs the line speed. Available when encoder setting is disabled.
Setting Range
3
Delay Distance
Inputs the moving distance of line from trigger input to the start of marking.
Setting Range
Moving Direction
Sensor
Reference
• Set a delay distance shorter than a marking interval.
1
0 to 3000.0mm
0.060 to 240.000 m/min
(LP-430 / LP-420 / LP-435 / LP-425 / LP-V10 / LP-V15)
0.060 to 170.000 m/min
(LP-410)
0.060 to 120.000 m/min
(LP-431 / LP-421 / LP-W052)
0.060 to 85.000 m/min
(LP-411)
0 to 500.00mm
Delay Distance
A
Marking Interval
Marking Trigger ON
ME-LP400V-OP-6
When the encoder is used
(Encoder signal: valid)
4
5
A
A
Marking Interval
1
6
223