Panasonic LP-V Series Operation And Maintenance Manual page 194

Laser marker
Hide thumbs Also See for LP-V Series:
Table of Contents

Advertisement

Description
5
Guard :
This setting is available when the inversion is enabled.
Select whether the guard pattern which is created outside of the code symbol is expanded with a certain width.
To improve the read rates of the code symbols, enable this setting.
Reference
• For GS1 DataBar Limited when this "Guard" setting is enabled and "2006" or "2011" is set in "Bar Code Setting" (P.257)
of Environment settings, the guard pattern is expanded with the certain width in addition to the specified width of ISO/
IEC 24724 2006 or 2011.
• For GS1 DataBar Limited when "Custom" is set in "Bar Code Setting" (P.257) of Environment settings, this "Guard" is
fixed to "None".
6
Human Readable Text :
Check the box to enable the function.
7
Detail :
Click this button to display the Human Readable Text Setting screen. Refer to "Human Readable Text" (P.203).
8
Auto :
This function button sub serves the code configuration By inputting the "Module Width" and "Bar Code Data",
this function is available. Pressing AUTO button displays the confirmation dialog box. On this screen, clicking
"Yes" sets both the bar code condition and laser condition automatically, and clicking "No" sets only the bar code
condition automatically. This AUTO setting becomes invalid by pressing "Cancel".
Refer to "Setting Value for AUTO Set" (P.324) for detail.
9
Separator Height/(W) :
Specifies the height of the separator between a multi-tiered bar code. Usually it is the same as the width of a
module.
Setting Range
10
Symbol Character in Row (GS1 DataBar Expanded Stacked only) :
Specifies the number of column for overlapping the bar code.
Setting Range
11
Bar Code Data :
Refer to "Code Type and Code Data" (P.190) for input characters.
Reference
• For GS1 DataBar, GS1 DataBar Limited and those composite codes, input 13-figure numbers as the code data. In
those human readable text, "01" as AI in the head of the text and the check digit (modulus10/weight 3-1) in the end of
the text are indicated automatically.
194
0.0 to 10.0
2 to 20 (For primary composite : 4 to 20.)
ME-LP400V-OP-6

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Lp-400 seriesLp-w series

Table of Contents