Processing Condition - Panasonic LP-V Series Operation And Maintenance Manual

Laser marker
Hide thumbs Also See for LP-V Series:
Table of Contents

Advertisement

4-10-5 Processing Condition

Description
1
Proc. Cond. No. (Processing Condition No.) :
Specifies up to 8 processing condition per one registered file.
Setting Range
2
Dashed Line :
To input the dashed line, enable this function. Clearing the check box marks the setting data with solid line.
Solid (part of dashed line) :
When dashed line is set, input the length of the solid part of the dashed line.
Setting Range
Blank (of dashed line) :
When dashed line is set, input the length of the blank of the dashed line.
Setting Range
3
Processing Element :
Indicates the processing condition set at the laser setting.
Up to 32 processing elements can be set per one number of processing condition.
4
INPUT :
Pressing INPUT button establishes the specified conditions.
5
DELETE :
Pressing DELETE button deletes the selected processing condition.
6
ALL DEL :
Pressing ALL DEL button deletes processing condition.
7
Type of the processing element:
Specifies the line type, its position and size.
1
7
2
3
4
5
0 to 7
0.010 to 90.000 mm
(LP-V10)
0.010 to 110.000 mm
(LP-430 / LP-420 / LP-410)
0.010 to 160.000 mm
(LP-435 / LP-425 / LP-V15)
0.010 to 55.000 mm
(LP-431 / LP-421 / LP-411 / LP-W052)
0.000 to 90.000 mm
(LP-V10)
0.000 to 110.000 mm
(LP-430 / LP-420 / LP-410)
0.000 to 160.000 mm
(LP-435 / LP-425 / LP-V15)
0.000 to 55.000 mm
(LP-431 / LP-421 / LP-411 / LP-W052)
Solid part of dashed line
ME-LP400V-OP-6
6
Blank of dashed line
207