Panasonic LP-V Series Operation And Maintenance Manual page 262

Laser marker
Hide thumbs Also See for LP-V Series:
Table of Contents

Advertisement

⿎ RS-232C
This screen specifies the environmental setting of the RS-232C. To perform RS-232C communication, use the [RS-232C]
tab and set the following items:
Reference
• For communication with external devices, select either RS-232C or Ethernet port. They cannot be used at the same
time, or switched.
1
4
7
Item
1
Baud Rate
2
Data Length
3
Parity
4
Stop Bits
5
Delimit
6
Check Sum
7
BCS Command
GS → FNC1
262
2
5
Description
:
Specifies the baud rate.
Setting entry
1200, 2400, 4800, 9600, 19200, 38400 [bps]
Initial setting
9600 bps
:
Indicates the data length. 8-bit fixed.
:
Specifies the parity.
Setting entry
None, Odd, Even
Initial setting
None
:
Specifies the stop bit.
Setting entry
1bit, 2bit
Initial setting
1 bit
:
Sets the delimiter (code to identify the end of telegraphic message).
Setting entry
CR, CR+LF
Initial setting
CR
:
Specify ON/OFF of check sum (error detection information).
Enable this function when using the check sum.
Check Sum indicates the lower 1-byte of adding result of value (binary) from the start code
to the last data by converting it to two characters for ASCII code.
:
This setting is available only when the barcode "GS1 DataMatrix" is used. To set the barcode
character by using serial communication command "BCS", select either "GS" (OFF) or "FNC1"
(ON) as the separator of AI data with the variable length.
ON: the separator of variable length AI data is "FNC1".
Setting Range
OFF: the separator of variable length AI data is "GS".
3
6
ME-LP400V-OP-6

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Lp-400 seriesLp-w series

Table of Contents