6 - 78 WiNG 5.5 Access Point System Reference Guide
6. Refer to the
Calibration Assignment
floor the access point is deployed on or building in its entirety. Both options are disabled by default.
7. Select
OK
to update the access point's Smart RF Basic configuration. Select
The Smart RF policy can be invoked at any point in the configuration process by selecting
from the upper, left-hand side, portion of the access point user interface.
8. Select
Channel and
updated.
Use the Channel and Power screen to refine Smart RF power settings over both the 5.0 GHz and 2.4 GHz radio bands and
select channel settings in respect to the access point's channel usage.
NOTE: The
when Custom is selected as the Sensitivity setting from the Basic Configuration screen.
9. Refer to the
Power Settings
GHz (802.11bg) radio.
5 GHz Minimum Power
5 GHz Maximum Power
field to define whether Smart RF Calibration and radio grouping is conducted by the
Power. Ensure the
Activate SMART RF Policy
Power Settings
and
Channel Settings
Figure 6-33 SMART RF - Channel and Power screen
field to define Smart RF recovery settings for the access point's 5.0 GHz (802.11a) and 2.4
Use the spinner control to select a 1 - 20 dBm minimum power level for Smart RF to assign
to a radio in the 5.0 GHz band. The default setting is 4 dBm.
Use the spinner control to select a 1 - 20 dBm maximum power level Smart RF can assign
a radio in the 5.0 GHz band. The default setting is 17 dBm.
Reset
to revert to the last saved configuration.
Activate SMART RF Policy
remains selected so the screen's parameters can be
parameters are only enabled