Low Limit of Light
Threshold
High Limit of Light
Threshold
6. Enable or disable the following
Enable Temperature
Sensor
Enable Motion Sensor
Enable Humidity Sensor
7. Define or override the following
Polling Interval for All
Sensors
8. Select
OK
to save the changes made to the environmental sensor screen. Select
configuration.
Set the low threshold limit (from 0 - 1,000 lux) to determine whether the lighting is off in
the AP8132's deployment location. The default is 100.
Set the upper threshold limit (from 100 - 10,000 lux) to determine whether the lighting is
on in the AP8132's deployment location. The default is 500.
Environmental
Sensors:
Select this option to enable the module's temperature sensor. Results are reported back
to the access point's Environment screens within the Statistics node. This setting is
enabled by default.
Select this option to enable the module's motion sensor. Results are reported back to the
access point's Environment screens within the Statistics node. This setting is enabled by
default.
Select this option to enable the module's humidity sensor. Results are reported back to the
access point's Environment screens within the Statistics node. This setting is enabled by
default.
Shared Configuration
setting:
Set an interval in either Seconds (1 - 100) or Minutes (1 - 2) for the time between all
environmental polling (both light and environment). The default setting is 5 seconds.