ABB ACH550-UH-011A-6 User Manual page 349

Table of Contents

Advertisement

Parameter
name
ACC/DEC 1/2
22 ACCEL/
SEL
DECEL
ACCELER
TIME 1
DECELER
TIME 1
RAMP SHAPE
1
ACCELER
TIME 2
DECELER
TIME 2
RAMP SHAPE
2
EMERG DEC
TIME
RAMP INPUT
0
23 SPEED
PROP GAIN
CONTROL
INTEGRATION
TIME
DERIVATION
TIME
ACC
COMPEN-
SATION
AUTOTUNE
RUN
CRIT SPEED
25 CRITICAL
SEL
SPEEDS
CRIT SPEED
1 LO
CRIT SPEED
1 HI
CRIT SPEED
2 LO
CRIT SPEED
2 HI
CRIT SPEED
3 LO
CRIT SPEED
3 HI
FLUX OPT
26 MOTOR
ENABLE
CONTROLS FLUX
BRAKING
IR COMP
VOLT
IR COMP
FREQ
U/F RATIO
SWITCHING
FREQ
SWITCH
FREQ CTRL
SLIP COMP
RATIO
NOISE
SMOOTHING
DC
STABILIZER
OVERMODUL
ATION
344
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
HVAC
default
Supply fan Return fan
Par.
1
2
index
2201
NOT SEL
NOT SEL
2202
30.0 s
15.0 s
2203
30.0 s
15.0 s
2204
0.0 s
0.0 s
2205
60.0 s
60.0 s
2206
60.0 s
60.0 s
2207
0.0 s
0.0 s
2208
1.0 s
1.0 s
2209
NOT SEL
NOT SEL
2301
5.00
5.00
2302
0.50 s
0.50 s
2303
0 ms
0 ms
2304
0.00 s
0.00 s
2305
OFF
OFF
2501
OFF
OFF
0 Hz /
0 Hz /
2502
0 rpm
0 rpm
0 Hz /
0 Hz /
2503
0 rpm
0 rpm
0 Hz /
0 Hz /
2504
0 rpm
0 rpm
0 Hz /
0 Hz /
2505
0 rpm
0 rpm
0 Hz /
0 Hz /
2506
0 rpm
0 rpm
0 Hz /
0 Hz /
2507
0 rpm
0 rpm
2601
ON
ON
2602
OFF
OFF
2603
0 V
0 V
2604
80%
80%
2605 SQUARED SQUARED SQUARED SQUARED SQUARED SQUARED
2606
4 kHz
4 kHz
2607
ON
ON
2608
0%
0%
2609
DISABLE
DISABLE
2619
DISABLE
DISABLE
2625
DISABLE
DISABLE
Parameter listing and descriptions
ACH550-01 User's Manual
Cooling
tower fan Condenser
3
4
NOT SEL
NOT SEL
NOT SEL
15.0 s
30.0 s
10.0 s
15.0 s
30.0 s
10.0 s
0.0 s
0.0 s
0.0 s
60.0 s
60.0 s
60.0 s
60.0 s
60.0 s
60.0 s
0.0 s
0.0 s
0.0 s
1.0 s
1.0 s
1.0 s
NOT SEL
NOT SEL
NOT SEL
5.00
5.00
5.00
0.50 s
0.50 s
0.50 s
0 ms
0 ms
0 ms
0.00 s
0.00 s
0.00 s
OFF
OFF
OFF
OFF
OFF
OFF
0 Hz /
0 Hz /
0 Hz /
0 rpm
0 rpm
0 rpm
0 Hz /
0 Hz /
0 Hz /
0 rpm
0 rpm
0 rpm
0 Hz /
0 Hz /
0 Hz /
0 rpm
0 rpm
0 rpm
0 Hz /
0 Hz /
0 Hz /
0 rpm
0 rpm
0 rpm
0 Hz /
0 Hz /
0 Hz /
0 rpm
0 rpm
0 rpm
0 Hz /
0 Hz /
0 Hz /
0 rpm
0 rpm
0 rpm
ON
ON
ON
OFF
OFF
OFF
0 V
0 V
0 V
80%
80%
80%
4 kHz
4 kHz
4 kHz
ON
ON
ON
0%
0%
0%
DISABLE
DISABLE
DISABLE
DISABLE
DISABLE
DISABLE
DISABLE
DISABLE
DISABLE
Booster
pump
5
6
NOT SEL
5.0 s
5.0 s
0.0 s
60.0 s
60.0 s
0.0 s
1.0 s
NOT SEL
5.00
0.50 s
0 ms
0.00 s
OFF
OFF
0 Hz /
0 rpm
0 Hz /
0 rpm
0 Hz /
0 rpm
0 Hz /
0 rpm
0 Hz /
0 rpm
0 Hz /
0 rpm
ON
OFF
0 V
80%
4 kHz
ON
0%
DISABLE
DISABLE
DISABLE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ach550-01Ach550

Table of Contents