Testing the Fuel Pump Capacity (continued)
Electrical System: Component Testing
When testing the fuel pump output, do not turn the key switch to
the START position.
7. Turn the key switch to the ON position and collect the fuel in the graduated
cylinder. Allow the pump to run for 15 seconds and then turn the switch
to the OFF position.
Note: The amount of fuel pumped in 15 seconds must be approximately
475 ml (16 fl oz).
8. Replace the fuel pump if output specification is not met.
If the fuel pump is replaced, ensure that replacement pump is the
correct pump for your Reelmaster by using your Parts Catalog. If
incorrect pump is used, the fuel system damage can occur.
9. Connect the fuel pump discharge hose to the fuel/water separator or filter.
Ensure to secure the hose with the hose clamp.
10. Reconnect electrical connector to the fuel stop solenoid.
11. Prime the fuel system; refer to Operator's Manual.
Fuel Pump Specifications
Pump Capacity
Pressure
Maximum Current Draw
IMPORTANT
IMPORTANT
1.9 L/minute (64 fl oz/minute)
48.3 kPa (7 psi)
2.0 A