ECC800 Data Center Controller
User Manual
Step 2 Enabling camera NTP synchronization.
The camera NTP synchronization function for the server is disabled by default. The camera
NTP synchronization function needs to be enabled for the server that connects to cameras.
After the camera NTP synchronization function is enabled, cameras will automatically
time-synchronize from their access servers.
1.
2.
3.
4.
5.
Step 3 (Optional) Deploying IVS in Stack Mode. For details, see
Mode.
Step 4 (Optional) Deploying MPUs in Cluster Mode. For details, see
Cluster
----End

5.8.2 Commissioning IPC6325 Cameras

Prerequisites
If multiple cameras are accessed, retain the connection of one camera and disconnect
connections from other cameras. After commissioning the connected camera, commission
other cameras in the same way.
Procedure
Step 1 Log in to the camera WebUI.
1.
Issue 07 (2020-03-16)
Log in to the OMU portal of the VCN as the Admin user.
Choose Maintenance > Unified Configuration.
Select the server that the camera needs to access, set Module name to SCU and
Parameter type to System property, and click Search.
Figure 5-29 Configuring Camera NTP Synchronization
In the search results, click Edit in the row where Parameter Name is NTPIPC and set
Value to 1.
Click Save. After the camera NTP synchronization function is enabled, the camera, after
being connected to the server, will automatically time-synchronize with the server.
Mode.
Configure the PC IP address and the camera IP address in the same network segment.
Enter the camera IP address (192.168.0.120 by default) in the address bar of the Internet
Explorer and press Enter button.