Installing The Shutoff Valve And Hoses For The Optional Spray Gun; Repositioning The Section Bypass Valves - Toro Multi Pro 1750 Installation Instructions Manual

Turf sprayer
Hide thumbs Also See for Multi Pro 1750:
Table of Contents

Advertisement

Figure 82
1. Outer boom section
2. Supply hose (outer-boom
section)
3. Barbed T-fitting
4. Assemble the right boom-supply hose onto the
T-fitting at the right-boom section
5. Secure the hose to the T-fitting with a hose clamp that
you removed in step
Hoses (page
11).
6. Repeat steps
3
through
at the left-boom section.
4. Hose clamp
5. R-clamp
(Figure
82).
1
of
Removing the Boom-Section
5
for the left boom-supply hose
17
Installing the Shutoff Valve
and Hoses for the Optional
Spray Gun Kit or Electric
Hose-Reel Kit
Parts needed for this procedure:
1
Cap and retrainer
1
Straight barbed fitting (1/2 inch)
1
Quick-connect fitting (socket)
2
Hose clamp 13 to 32 mm (1/2 to 1-1/4 inches)
1
Hose—1.3 x 762 cm (1/2 x 300 inches)
1
Hose—1.3 x 180 cm (1/2 x 83 inches)
2
2412-36 Hose clamp 6 to 11 mm (1/4 to 7/16 inch)
1
Bypass shutoff valve
Section bypass hose—2.5 x 146 cm (1 x 57-1/2
1
inches)
Repositioning the Section Bypass
Valves
1. Remove the retainer that secures the plug to the
socketed quick-connect fitting of the bypass manifold
(Figure
83).
Note: Retain the retainer for installation in
the Section Bypass Hose—Machines with the Optional
Spray Gun Kit or the Optional Electric Hose Reel Kit
(page
46).