Removing The Agitation, Rate, And Master-Spray Valves; Removing The Bracket For The Agitation Throttle Mount; Disconnecting The Return, Sprayer-Supply, And Bypass Hoses - Toro Multi Pro 1750 Installation Instructions Manual

Turf sprayer
Hide thumbs Also See for Multi Pro 1750:
Table of Contents

Advertisement

Removing the Bracket for the Agitation
Throttle Mount
1. Remove the 2 flange-head bolts (5/16 x 5/8 inch) that
secure the agitation throttle valve to the throttle-valve
bracket
(Figure
21).
Figure 21
1. Agitation supply hose
2. Flange-head bolt (5/16 x
5/8 inch)
2. Remove the 2 flange-head bolts (5/16 x 3/4 inch) that
secure the throttle-valve bracket to the throttle-valve
mount, and remove the bracket
Note: You no longer need the 4 flange-head bolts and
throttle-valve bracket.
Figure 22
1. Mount (throttle-valve
bracket)
2. Bracket (throttle valve)
3. Bracket (throttle valve)
4. Agitation throttle valve
(Figure
22).
3. Flange-head bolt (5/16 x
3/4 inch)
7
Removing the Agitation, Rate,
and Master-Spray Valves
No Parts Required
Disconnecting the Return,
Sprayer-Supply, and Bypass Hoses
1. At the back of the machine, remove the retainer that
secures the 90° barbed fitting of the return hose to the
T-fitting located inboard of the pressure-relief valve
(Figure
23).
Note: Retain the retainers for installation in
the Return Hose (page
1. Pressure-relief valve
2. 90° barbed fitting (return
hose)
3. Front of the machine
2. Remove the 90° barbed fitting from the T-fitting
(Figure
23).
3. Remove the retainer that secures the 90° barbed fitting
of the sprayer supply hose to the T-fitting located
forward of the pressure-relief valve
Note: Retain the retainers for installation in
the Sprayer Supply Hose—Machine without the
Optional Eductor Kit (page
14
31).
Figure 23
4. T-fitting
5. Retainer
(Figure
24).
34).