Installing The Right Spray-Valve Connector - Toro Multi Pro 1750 Installation Instructions Manual

Turf sprayer
Hide thumbs Also See for Multi Pro 1750:
Table of Contents

Advertisement

Figure 31
1. Inline-fuse block
2. Positioned convoluted
tubing
4. Align the inline-fuse block to the convoluted tubing as
shown in
Figure 31
and secure the fuse block to the
tubing with a cable tie.
5. Cut the DIN connector harness below the DIN
connector
(Figure
32)
Note: Cut the harness as close to the connector.
3. Cable tie
1. DIN connector
6. Remove a 70 mm (2-3/4 inches) section of the
sheathing from the DIN connector harness
1. Cable sheathing 70 mm
(2-3/4 inches)
2. Wire splice (factory made)
7. Remove 8 mm (5/16 inch) of insulation from the 3
wires of the DIN connector harness
8. Repeat steps
1
though
labels
CENTER SPRAY VALVE
,
VALVE
AGITATION VALVE
Installing the Right Spray-Valve
Connector
1. Align the wire insulation colors of the DIN harness
to the wire insulation colors of the 3-pin adapter for
the right spray valve as shown in the wire table for the
right spray valve.
17
Figure 32
(Figure
Figure 33
3. Removed section of wire
insulation—8 mm (5/16
inch)
(Figure
7
for the wire harness branches
,
LEFT SPRAY VALVE
, and
MASTER SPRAY VALVE
33).
33).
,
RATE
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

136-0372

Table of Contents