Mitsubishi Electric IQSS-R-E Reference Manual page 130

Iq sensor solution, melsec iq-r/iq-f/l/q series, got2000, melipc
Table of Contents

Advertisement

Example of a data restoration (bridge module (NZ2AW1GFAL))
■Example of a system configuration
The following shows the example of a system configuration for data restoration.
Restoration target
• Target module type: CC-Link IE Field Network
• Execution unit: Station sub-ID
• Folder number setting: 24
• Target device (target module): Start I/O No.30
• Target device (station number): Station No. 1
• Target device (station sub-ID number): Station sub-ID 517
• Operation setting on error: Stop
5 CC-Link IE Field Network
128
5.5 Backing up/Restoring Data of Devices Supporting iQSS
CC-Link IE Field Network master/local module start I/O number 30
Station No. 1
CC-Link IE Field Network-AnyWireASLINK bridge module
24V
0V
DP
DN
LG
Address 1 to 4
ID513 (201H) to
ID516 (204H)
(Station sub-ID 513
to 516)
Address 5
ID517(205H)
(Station sub-ID 517)