Bay control REC670 2.2 ANSI
Application manual
Autorecloser for 1 phase, 2 phase and/or 3 phase operation
SMBRREC (79).................................................................................... 323
Identification.................................................................................... 323
Application....................................................................................... 324
Auto reclosing operation Off and On.......................................... 327
Initiate auto reclosing and conditions for start of a reclosing
cycle........................................................................................... 328
Initiate auto reclosing from circuit breaker open information...... 328
Blocking of the auto recloser...................................................... 328
Long trip signal........................................................................... 329
Maximum number of reclosing shots..........................................330
ARMode = 3ph, (normal setting for a three-phase shot)............ 330
ARMode = 1/2/3ph ..................................................................... 330
ARMode = 1/2ph , 1-phase or 2-phase reclosing in the
first shot...................................................................................... 331
ARMode = 1ph+1*2ph, 1-phase or 2-phase reclosing in the
first shot...................................................................................... 331
ARMode = 1/2ph + 1*3ph, 1-phase, 2-phase or 3-phase
reclosing in the first shot.............................................................331
ARMode = 1ph + 1*2/3ph, 1-phase, 2-phase or 3-phase
reclosing in the first shot.............................................................331
External selection of auto reclosing mode..................................332
Auto reclosing reset timer...........................................................333
Pulsing of the circuit breaker closing command and counter..... 333
Transient fault.............................................................................333
Permanent fault and reclosing unsuccessful signal....................333
Lock-out initiation........................................................................334
Evolving fault.............................................................................. 335
Thermal overload protection holding the auto recloser back......336
Setting guidelines............................................................................ 336
Configuration.............................................................................. 336
Auto recloser settings................................................................. 345
Apparatus control APC......................................................................... 350
Application....................................................................................... 350
Bay control QCBAY.................................................................... 356
Switch controller SCSWI............................................................ 357
Switches SXCBR/SXSWI........................................................... 357
Proxy for signals from switching device via GOOSE
XLNPROXY................................................................................ 358