FOR:
Purpose: Determines whether the common bell relay contacts have an interrupted or
continuous closure when activated. If interrupted is chosen, the relay follows an internal
ring pattern of one second closed followed by three seconds open.
By default, all common bell relay pairs are assigned as:
DCS
Compact II
380x
363–365
ACTION
1. Open programming and select 204
Display shows current setting
2. Dial common bell number
OR
Press VOLUME keys to make selection of
common bell numbers and press RIGHT soft key
to advance cursor
3. Dial 0 for continuous or 1 for interrupted operation
OR
Press VOLUME keys to scroll through options
Press RIGHT soft key to return to step 2
4. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC
Default Data:
Related Items:
COMMON BELL CONTROL
ALL SYSTEMS
816
408 / 408i
362
Continuous
MMC 203 Assign UA Device
MMC 219 Common Relay Service Type
MMC 601 Assign Station Group
MMC 204 (Page 1 of 1)
iDCS500
361
380x
DISPLAY
[3801]COM. BELL
CONTINUOUS
OR
[363] COM/LD BELL
CONTINUOUS
[3801]COM. BELL
INTERRUPTED
OR
[363] COM/LD BELL
INTERRUPTED
MMC PROGRAMS
FEBRUARY 2004
iDCS100
OS500
363–365