Ring Modes - Samsung DCS Programming Manual

Combined systems
Hide thumbs Also See for DCS:
Table of Contents

Advertisement

SAMSUNG
COMBINED SYSTEMS PROGRAMMING MANUAL
UCD GROUPS
Maximum number of UCD groups that can be programmed is:
DCS
CI
CII
816
iDCS100
iDCS500(M)
iDCS500(L)
OS500 (S/M)
OS500 (L)
Options for UCD groups are set in

RING MODES

0
SEQUENTIAL
1
DISTRIBUTE
2
UNCONDITIONAL
Note: When a group is called, or a caller is transferred to a group, ringback is sent to the caller.
Calls to a group do not follow the call forwarding instructions of any stations in the group.
FEATURE KEY
0
TYPE
1
RING
2
OVERFLOW
3
GROUP TRANSFER
4
NEXT PORT
5
MEMBER
6
NEXT HUNT
7
GROUP BUSY
8
GROUP AUTO ANSWER
Note:
1
iDCS500 'L' and OS500 systems only
2
iDCS and OS500 systems only
10, created from last 10 station groups (520–529)
10, created from any station group (501–529)
5, created from the last 10 station groups (510–519)
3, created from the last 3 station groups (507–509)
10, created from any group
10, created from any group
20, created from any group
20, created from any group
20, created from any group
MMC
The first idle station listed in the group will ring. If the first is
busy, the next idle station will ring.
The first call will ring the first station listed in the group. The
next call will ring the next station listed in the group.
All the stations listed in the group will ring. (Busy stations
will receive off-hook ring, if set in
number of stations allowed to ring unconditionally for a
group is: DCS=32, Compact II=10, 816=16, 408/408i=8,
iDCS=32, OS500=32
Group type
Ring mode
Timer for overflow to 'Next Port'
Timer for recall of calls transferred to group
Overflow port (station, group, common bell, ring over
page)
Members of group (e.g. station numbers)
Timer for ringing a station before hunting for next
member
If set ON, generates busy tone when all station group
members of Sequential or Distribute ring groups are
2
busy
If set ON, stations will Auto Answer calls to the group
MMC 601 (Page 2 of 3)
607.
1
(refer to option SGR INC BUSY in
MMC PROGRAMS
FEBRUARY 2004
MMC
300.) The maximum
MMC
210)

Hide quick links: