Samsung DCS Programming Manual page 396

Combined systems
Hide thumbs Also See for DCS:
Table of Contents

Advertisement

SAMSUNG
COMBINED SYSTEMS PROGRAMMING MANUAL
ALM CODE
ALARM
MJD09
Bit Error Alarm
MJD10
NTWRK Event
MJD11
SPID Init Error
MJD12
SPID Init Rec
MJD13
LPBK Error
MJD14
LPBK Recovery
MJD15
BRI DL Unavail
MJD16
BRI DL Recovery
MJD17
RAM Error
MJD18
E1 Restart
MJD19
PRI Restart
MJD20
BRI Restart
MJD21
PCM Loss
MJD22
PCM Recovery
MNF01
Card Out
MNF02
Card In
MNF03
IPC Error
MNF04
Trunk Fault
MNF05
Trunk Recovery
Alarm is activated when the when error rate exceeds 1x10-6 er-
rors. Note: 1x10-6 is threshold for minor alarm; 1 x 10-3 is
threshold for major alarm errors on E1, PRI or BRI.
Alarm Data = Cabinet, Slot (Cx-Syy)
An Implausible event has occurred on the PRI or BRI Network
digital line. Protocols do not match or subscriber ID mismatch.
Alarm Data = Cabinet, Slot (Cx-Syy)
The BRI received an error from the network
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
The BRI has recovered from an error on the network
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
Internal on-demand loopback failed.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
Internal on-demand loopback test passed.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
A BRI data link is out of service.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
A BRI data link is back in service.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
An error has occurred in the TEPRI or BRI card RAM.
Alarm Data = Cabinet, Slot (Cx-Syy)
The E1 card has restarted
Alarm Data = Cabinet, Slot (Cx-Syy)
The PRI card has restarted
Alarm Data = Cabinet, Slot (Cx-Syy)
The BRI card has restarted
Alarm Data = Cabinet, Slot (Cx-Syy)
Loss of PCM coding on a digital facility.
Alarm Data = Cabinet, Slot (Cx-Syy)
Recovery of PCM coding on a digital facility.
Alarm Data = Cabinet, Slot (Cx-Syy)
A circuit card mounted in a universal slot has been removed from
service or is not recognised by the system
Alarm Data = Cabinet,Slot (Cx-Syy)
A circuit card mounted in a universal slot has been returned to
service.
Alarm Data = Cabinet, Slot (Cx-Syy)
Inter processor communication error has occurred.
Alarm Data = Cabinet-Slot (Cx-Syy)
Out of service trunk detected via loop detect. Internal CODEC
test.
Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)
Out of service trunk detected via loop detected as out of service
is now operational.
Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)
MMC 851 (Page 4 of 5)
MMC PROGRAMS
FEBRUARY 2004
DEFINITION

Hide quick links:

Advertisement

Table of Contents
loading