PCV Valve Inspection
1) Remove PCV valve referring to "PCV Valve Removal
and Installation".
2) Connect PCV valve to hose and install plug to
cylinder head cover hole.
3) Run engine at idle.
4) Place your finger over end of PCV valve (1) to check
for vacuum.
If there is no vacuum, check for clogged valve.
Replace as necessary.
1
Tightening Torque Specifications
Fastening part
PCV valve
NOTE
The specified tightening torque is also described in the following.
"EVAP System Components"
Reference:
For the tightening torque of fastener not specified in this section, refer to "Fasteners Information in Section 0A".
Recommended Service Material
Material
Water tight sealant
Special Tool
09917–47011
Vacuum pump gauge
/
S6RW0C1206016
I5JA01121009-01
Specifications
Special Tools and Equipment
SUZUKI recommended product or Specification
SUZUKI Bond No.1207F
Aux. Emission Control Devices:
5) After checking vacuum, stop engine and remove
PCV valve (1).
Shake valve and listen for rattle of check needle
inside the valve. If valve does not rattle, replace PCV
valve.
1
6) After checking, remove plug and install PCV valve
referring to "PCV Valve Removal and Installation".
7) Install air cleaner referring to "Air Cleaner Assembly
Removal and Installation in Section 1D".
Tightening torque
N⋅m
kgf-m
27
2.7
P/No.: 99000–31250
SUZUKI scan tool (SUZUKI-
SDT)
—
This kit includes following
items. 1. SUZUKI-SDT 2.
DLC3 cable 3. USB cable 4.
AC/DC power supply 5.
Voltage meter probe 6.
Storage case
I4JA01121012-01
S6RW0C1207001
Note
lb-ft
19.5
S6RW0C1208001
Note
S6RW0C1208002
6
1
3
5
1B-6
2
4