1J-9 Charging System:
Installation
1) Loosen tensioner by turning the tensioner pulley (2)
clockwise.
2) While holding the tensioner, install generator belt (1).
3) Install right side engine under cover.
NOTE
• Make sure that the belt fits each pulley's
groove properly.
• After installing generator belt, make sure
that tension indicator is within standard
range referring to "Water Pump and
Generator Drive Belt On-Vehicle
Inspection".

Generator Unit Components

1. "B" terminal wire
2. coupler
3. Water pump and generator drive belt
4. Generator mounting bolt
3. Tensioner pulley bolt
5. Generator pivot bolt
6. "B" terminal nut
7. Generator cover
8. Generator
I3TR011A4001-01
S6RW0C1A06005
I7RW011A0002-01
: 5.0 N⋅m (0.5 kgf-m, 4.0 lb-ft)
: 52.5 N⋅m (5.25 kgf-m, 38.0 lb-ft)
: 25 N⋅m (2.5 kgf-m, 18.5 lb-ft)