10.9 RPK - FSN(H)3M Wall mounted

10.9.1 Removal of the air filter


For RPK-(0.8-1.5)FSN(H)3M
Open the flat panel. Hold the both sides of flat panel and pull it up

For for RPK-(2.0-4.0)FSN(H)3M

10.9.2 Removal of the front panel

C A U T I O N
• Cover completely the front panel with a sheet of plastic to protect it during installation work.
• The shaft is coated with a lubricant. If it gets in eyes or contacts with skin, flash them out with water immedi-
ately. Also consult a doctor if necessary. Wash your hands thoroughly after handling the shaft.

For RPK-(0.8-1.5)FSN(H)3M
1 Remove the air filter according to the "Removing Air Filter." chapter.
2 Open the flat panel fully and slightly extend the right arm shaft outward. After the shaft is removed from the front panel,
pull the flat panel frontward with the right arm shaft slightly extended outward and then remove the flat panel.
3 Remove 2 bushes and then 2 screws. Pull the lower side of the front panel forward to release the catches. Then
remove the front panel carefully so that it does not touch the horizontal louver attached to the air outlet.
4 Slightly lift the front panel up to release the catches (four portions) on the upper side of the unit. Then pull the front
panel forward to remove it
N O T E
When releasing the catches, snap sound is heard. This is the sound made when the catches are released and so there
are no safety concerns.