SYSTEM CONFIGURATION
Edit
CONNECT SEQUENCE
Enabled
Priority
Sequence
Sequence Number
Edit
DISCONNECT SEQUENCE
Enabled
Priority
Sequence
Sequence Number
Edit
AUTO LOGOUT
Enabled
Auto Logout
86
Used to edit the sequence selected for logout.
When enabled, triggers a sequence to run when
communication is established to this keyboard.
Sets the priority level for the keyboard connection sequence.
Priority can be set to a number between 0 and 255 with 0
being the highest priority. Sequences are activated based on
their priority. For example, if a sequence with priority 3 has
a camera switched to a monitor, and the sequence has
locked the monitor, any sequence with a priority greater than
3 would not be able to switch a camera to that same monitor.
Drop down box used to select (by name) the sequence to run
when keyboard connection is established. Sequence
number selected correlates with sequence name.
Drop down box used to select (by number) the sequence to
run when keyboard connection is established. Sequence
number selected correlates with sequence name.
Used to edit the sequence selected for keyboard connection.
When enabled, triggers a sequence to run when
communication is lost to this keyboard.
Sets the priority level for keyboard connection loss.
Priority can be set to a number between 0 and 255
with 0 being the highest priority. Sequences are activated
based on their priority. For example, if a sequence with a
priority 3 has a camera switched to a monitor, and the
sequence has locked the monitor, any sequence with a
priority greater than 3 would not be able to switch a camera
to that same monitor.
Drop down box used to select (by name) the sequence to
run when keyboard connection is lost. Sequence number
selected correlates with sequence name.
Drop down box used to select (by number) the sequence to
run when keyboard connection is lost. Sequence number
selected correlates with sequence name.
Used to edit the sequence selected for lost keyboard
connection.
When enabled, sets up automatic logout of a user after a
period of inactivity.
Used to set the period of inactivity (in minutes) after which
the user will be logged out.