Alarmq (Alarm Queues); Alarm Queue Configuration - Honeywell VideoBloX User Manual

Hide thumbs Also See for VideoBloX:
Table of Contents

Advertisement

For example, default values are shown as 1, 2, 3, 4, etc. If "2" is revised to be "23", the
list will display as 1, 23, 3, 4, etc. and the original row 23 remains the same. We
recommend that the Group Number field NOT be revised.
2. Modify the text in the Group Name field to a meaningful means of grouping alarms.
Once the group name is modified, the values will be carried over into other applicable
windows.
3. Select
Alarm Q (ALARM QUEUES)

Alarm Queue Configuration

VideoBloX has an Alarm Queue system for prioritizing and displaying Alarms.
There are 32 Queues, each of which is associated with a Keyboard and up to four
Monitors. The system will display the highest priority alarm on the first available monitor.
Alarms of equal or lower priority will be displayed on the secondary alarm monitors.
Alarms are added to the Queue by use of a sequence. When the alarm is activated, a
sequence is triggered. The sequence must include the step ALARMQ with the
parameters of "Alarm Q Number," "Alarm Number," and "Alarm State".
Alarms will remain in the Queue until the Alarm Ack (Acknowledged) and key is activated,
at which point that alarm will be removed from the Queue.
An Alarm can appear in multiple Queues and its priority is set by the Alarm trigger event.
The fields necessary to configure Alarm Queues are on the Alarm Q screen.