Configuring A Tape Volume Group; Viewing Cisco Sme Cluster, Internal, And Transport Information - Cisco AJ732A - MDS 9134 Fabric Switch Configuration Manual

Cisco mds 9000 family storage media encryption configuration guide - release 4.x (ol-18091-01, february 2009)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Configuring a Tape Volume Group

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Configuring a Tape Volume Group
A tape volume group is a group of tapes that are categorized usually by function. For example, HR1
could be the designated tape volume group for all Human Resource backup tapes; EM1 could be the
designated tape volume group for all e-mail backup tapes.
Adding tape groups allows you to select the VSANs, hosts, storage devices, and paths that SME will use
for encrypted data. For example, adding a tape group for HR data sets the mapping for SME to transfer
data from the HR hosts to the dedicated HR backup tapes.
To configure a tape volume group, follow these steps:
Command
Step 1
switch# config t
Step 2
switch(config)# sme cluster clustername1
switch(config-sme-cl)#
Step 3
switch(config-sme-cl)# tape-bkgrp groupname1
switch(config-sme-cl-tape-bkgrp)#
Step 4
switch(config-sme-cl-tape-bkgrp)# tape-device
devicename1
switch(config-sme-cl-tape-bkgrp-tapedevice)#
Step 5
switch(config-sme-cl-tape-bkgrp-tapedevice)#
tape-device devicename1 D
switch(config-sme-cl-tape-bkgrp-tapedevice)#
Step 6
switch(config-sme-cl-tape-bkgrp-tapedevice)#
host 10:00:00:00:c9:4e:19:ed target
2f:ff:00:06:2b:10:c2:e2 vsan 4093 lun 0
fabric f1
switch(config-sme-cl-tape-bkgrp-tapedevice)#
Step 7
switch(config-sme-cl-tape-bkgrp-tapedevice)#
enable

Viewing Cisco SME Cluster, Internal, and Transport Information

To verify Cisco SME cluster configurations, you can use the show sme command to view a specific
cluster configuration, internal information, and transport information.
A sample output of the show sme cluster command follows:
switch# show sme cluster clustername1
SME Cluster is clustername1
Cluster ID is 2e:00:00:05:30:01:ad:f4
Cluster is Operational
Cluster is Not Shutdown
Cluster config version is 27
Security mode is basic
Cluster status is online
Total Nodes are 1
Recovery Scheme is 1 out of 1
Fabric[0] is f1
CKMC server has not been provisioned
Master Key GUID is 8c57a8d82d2098ee-3b27-6c2b116a950e, Version: 0
Shared Key Mode is Enabled
Auto Vol Group is Not Enabled
Cisco MDS 9000 Family Storage Media Encryption Configuration Guide
7-8
Chapter 7
Using the Command Line Interface to Configure SME
Purpose
Enters configuration mode.
Specifies the cluster and enters SME cluster
configuration submode.
Specifies the tape volume group and enters the
SME tape volume group submode.
Specifies the tape device name and enters the
SME tape device submode.
Specifies the tape cartridge identifier.
Specifies the host and target, the VSAN, LUN
and the fabric (f1) for the tape volume group.
Enables the tape device.
OL-18091-01, Cisco MDS NX-OS Release 4.x

Advertisement

Table of Contents
loading

Table of Contents