Connecting Alarm Indicators
Figure 3-27
Remove the safety cover by lifting it up and out from the chassis
Step 2
Figure 3-28
Strip not more than 0.4 inches (10 mm) of insulation off the ends of the alarm indicator wire
Step 3
(Figure
Connect one set of alarm indicator wires to the alarm terminal block as follows (see
Step 4
Connect one lead to the common (COM) terminal.
a.
b.
Connect the other lead to the normally closed (NC) or normally open (NO) terminal.
Figure 3-29
Caution
router in series with other equipment for the alarm indicators, use the normally closed (NC) terminals.
If you are wiring the router in parallel with other equipment for the alarm indicators, use the NO
terminals.