Subwoofer output and air flow
Air intake area and subwoofer output
The ventilation air intake is close to the floor. It
aligns with the four subwoofers, which need an
opening toward the room to provide excellent
audio quality.
The opening must have the exact height and
position as shown in the illustration.
You may have studs in front of some of the risers
in the air intake area, as long as you don't cover
the ducts from the subwoofers.
We provide subwoofer grille elements for the air
intake area.
Air outlet area
The ventilation air outlet is at the top. It is created
with a gap or opening toward the ceiling. The
minimum size is shown in the illustration.
Air outlet area
Air intake area
and subwoofer
output
Minimum 3.57 m (140.6 in.)
3.57 m (140.6 in.)
Minimum 20 mm (0.79 in.)
90 mm (3.54 in.)
97