24.6. Hang the screen onto the screen mount module in the display cavity
Risk of personal injury
There is a potential hazard risk tied
to the gas springs in the screen
mount modules when installing or
dismantling the system. There is
no risk involved when following the
Install Guide step by step, but if
caution is not taken regarding the
screen mount safety brackets, there
is a chance of personal injury.
To help lifting the screen with the
screen mount module, the gas
springs store a lot of energy. If the
screen mount safety brackets are
moved out of the
Safe Mode
position
before the screen is mounted, the
screen mount module can shoot out
at high speed, potentially causing
harm. The same goes if one tries to
remove or dismantle the gas springs
from the product.
To avoid the risk of personal injury:
Do not disassemble any of the
pre-assembled parts of a display
cavity at any time.
Do not move the screen mount
safety brackets out of the
Safe Mode
position (transport
position) before the main screens
are mounted.
74
Lift screen onto bracket
Screen in place