Restoring The Panel To Factory Default Settings; Resetting The Panel - Honeywell MPA1 User Manual

Access control unit
Table of Contents

Advertisement

100 |
MPA1 User Guide
If the Secondary panel comes back on line the panel will not be serviced at the time of the
restore.
The "Panel Only" restore will only restore "Panel-specific data" to the particular panel.

Restoring the Panel to Factory Default Settings

Resetting the Panel

1.
www.honeywell.com/security
a.
Press the Reset button continuously for 30seconds. While Pressing the reset
button, the Run LED flickers fast.
b.
Once the reset operation is complete, Run LED will turn OFF and turns ON again.
The turn OFF and turn ON will indicate the reset operation is complete
c.
Once it is turns ON, release the Reset button.
d.
The panel is now reset to the original factory default values.
Navigate to the Settings panel:
• Dashboard > Panels > Settings, or
• Menu > Panel Configuration > Settings.