122 |
MPA1 User Guide
Table 7-4
Overriding requirements
The electronic access control system shall not prohibit the free exit granted by
other emergency systems (e.g. fire, environmental)
Table 7-5
System self-protection requirements
Memory stored information (settings) shall be kept for the indicated minimum
period of time in case of total power loss (except for loss of data retention
battery)
Following a total loss of power automatic restart of the access control system is
required upon primary power source restoral
If full functionality of the access control unit cannot be restored (data
corrupted or lost) following the automatic restart a trouble condition shall be
annunciated
Means of access to the internal elements of components of an access control
system shall require the use of a tool
The enclosures of the EACS components accessible from outside the controlled
area shall meet the required IP and IK ratings
There shall be separate access levels that categorize the ability of the operators
to perform different functions in the system. Minimum number of logical
access levels is:
The minimum number of required characters for logical access by memorized
information only shall be as indicated (N=numeric/A=alphanumeric)
Either failure or restoration of the communication channel shall not result in
the release of an access point
Failure of communication with monitoring console shall not interrupt the
access decision process
Processing rules stored in an access point reader shall not be visible to system
users
Light or sound keystroke keypad activation indicators shall not be a direct
representation of actual codes, but shall be identical in pitch and duration
Data entry system validation. System shall provide annunciation when invalid
data has been entered during configuration mode at the monitoring console
Access to the configuration mode shall time out after a pre-set period of
inactivity
Table 7-6
Power supply requirements
Following an extended primary power source failure (system shutdown
occurred) and restoration of power, rechargeable batteries shall be recharged
to 80 % of rated capacity within 24 hours and 100 % of rated capacity within
72 hours
www.honeywell.com/security
Yes/No
Grade 1 OP/M
Yes
M
Yes/No
Grade 1 OP/M
Yes
M
Yes
M
Yes
M
Yes
M
Yes
M
Yes
M
Yes
M
Yes
M
Yes
M
yes
M
Yes
M
Yes
M
Yes
M
Yes/No
Grade 1 OP/M
N/A
M