Honeywell MPA1 User Manual page 23

Access control unit
Table of Contents

Advertisement

3.
Table 2-2
WIN-PAK Host/Loop Communications Mode Settings
Host/Loop Setting
Host
Connection Type
Communication
Type
Host IP Address
Port Number
Generate Key
Disable Encryption
Encryption Key
4.
Setting the Communication Mode to Web
1.
2.
Configure the following host settings:
Description
Specifies the type of physical connection between the host and the
Primary panel.
If you are connecting from a host software system such as WIN-PAK,
select one of the following two connection options:
Direct via TCP/IP – Host initiates connection to panel.
Reverse TCP/IP – Panel connects directly to the host system using the
TCP/IP protocol. You must enter the host IP address in the Host IP
Address field. Panel initiates connection to host.
Specifies the type of communications.
Ack/NAK – Provides a response (either an acknowledgment or a
non-acknowledgment) in a transmission between the host and panel(s).
This is the recommended communications type.
Non Ack/NAK – Does not provide a response (either an acknowledgment
or a non-acknowledgment) in a transmission between the host and
panel(s). Normally used in troubleshooting only.
Enter the host system (or WIN-PAK server) IP address here if you selected
Reverse TCP/IP in the Connection Type field on this screen.
Specifies the port number for the Ethernet port. Port 2101 is Encrypted
(default). Port 3001 is Direct TCIP/IP. Port 5001 is Reverse TCP/IP.
Click to create and display a new encryption key.
Note
Whenever this box is checked and the page is saved, the new key
must be entered in WIN-PAK.
Select to disable encrypted communication between MPA1 Primary and
WIN-PAK Host. Disabling encryption creates an insecure system and is
not recommended.
This is the password/key used to encrypt communications between
Primary and WIN-PAK Host. You must enter this password on WIN-PAK
Host.
Click Save.
Navigate to Host/Loop Communications:
Dashboard > Panels > Host/Loop Communications, or
Menu > Panel Configuration > Host/Loop Communications.
Click to select Web.
Document 800-26311_ A - April 2020