Note
The duress output feature requires the following configurations:
Duress must be enabled on the Panel Configuration > Settings >
Behaviour Settings tab. See
A schedule/schedule must be selected for Card and PIN in the Doors
configuration.
6.
Enable or Disable Reader B. The default setting is Disabled. A confirmation message
appears. Click OK to enable Reader B.
Use an Reader B if a door has readers on both sides (inside and outside).
7.
Click Save.
Note
Should a conflict arise among the schedules set in the Access
Modes and Schedules section, priority is given in the following order:
Disable Reader
Lockdown Reader
Card and PIN
Card or PIN
PIN only
Card only
Therefore, the Disabled schedule has highest priority, and the Card
Only schedule has lowest priority.
Note
Readers must be enabled in two places, in Panel Configuration and here. Go
to Panel Configuration > Settings > Behaviour Settings tab. See
on
page
28.
Note
The access mode defined here for the door can be overridden by a card
assigned with a VIP card type. (See
information about assigning a VIP card type.)
Configuring Door Inputs
The Inputs tab allows you to configure the following settings:
Input Name
Input Modes
Shunt and Debounce
Scheduling
Figure 2-10
on
page
28.
Configuring People on page 66
Document 800-26311_ A - April 2020
| 47