(f)
Make sure that the minimum current is 2 A for a rotation speed of 15000 rpm.
NOTE: When you measure the current and the rotation speed, make sure that the
(g)
If necessary, adjust the position of the detection board (01-450).
(h)
If the results are correct, lock the detection board (01-450):
1
Remove one screw (01-460).
2
Apply a layer of adhesive material (M38B) on the threaded part of the screw (01-460).
3
Torque the screw (01-460) to the specified value (Ref. TASK 21-22-91-820-802-A01).
4
Do steps 1 thru 3 again with the two other screws (01-460), one after the other.
The document reference is online, please check the correspondence between the online documentation and the printed version.
COMPONENT MAINTENANCE MANUAL
00001059
voltage stays at 28 VDC.
21-22-91
Page 7006
Dec 15/06