Honeywell LMB HYPER 120-03 Component Maintenance Manual With Illustrated Parts List page 116

Table of Contents

Advertisement

– near a highway, an airport or a railway,
– near high power rotating machine.
(d)
Store the fans with the main shaft of the rotating S/A in the horizontal position.
SUBTASK 21-22-91-550-002-A01
(3)
Destorage
CAUTION: AT EACH DESTORAGE, YOU MUST CHECK THERE IS NO LUBRICANT IN
(a)
Running-in of the fans is done at factory. The fans need no special care on the initial or
later starts.
(b)
Fans are fitted with lubricated-for-life bearings. These bearings do not need any
lubrication on the destorage and operation phases.
(c)
After 6 years of storage, the fan must be repaired, by replacing the components the
expiry date of which is reached.
(d)
After unstorage, replacement of expired components, or before use, check for good
operation of the fan carrying out the test described in the TESTING AND FAULT
ISOLATION page block.
E.
Close-up
Not applicable
The document reference is online, please check the correspondence between the online documentation and the printed version.
COMPONENT MAINTENANCE MANUAL
00001059
THE PLASTIC PACKING OR ON THE EQUIPMENT. IF THERE IS LUBRICANT
LEAKAGE, REPLACE THE BEARINGS (REF. SUBTASK 21-22-91-010-005-A01)
AND (REF. SUBTASK 21-22-91-410-001-A01).
21-22-91
Page 15002
Dec 15/06

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

00001059 amdt b00001059 amdt c

Table of Contents