Close-Up - Honeywell LMB HYPER 120-03 Component Maintenance Manual With Illustrated Parts List

Table of Contents

Advertisement

DEFECT
The motor turns less
The adjustment of the detection board
than one round then
(01-450) is not correct.
stops.
The electronic boards are defective.
The motor does not
start each time.
The motor turns a
few seconds then
stops.
E.

Close-up

Not applicable
The document reference is online, please check the correspondence between the online documentation and the printed version.
COMPONENT MAINTENANCE MANUAL
00001059
POSSIBLE CAUSE
CORRECTION
Adjust the position of the detection
board (01-450) (Ref. SUBTASK
21-22-91-820-001-A01).
Replace the power board (01-370).
Remove the power board
(01-370) (Ref. SUBTASK
21-22-91-010-004-A01) or (Ref.
SUBTASK 21-22-91-010-004-B01).
Install the power board (01-370) (Ref.
SUBTASK 21-22-91-410-002-A01).
Replace the control board (01-330).
Remove the control board
(01-330) (Ref. SUBTASK
21-22-91-010-003-A01) or (Ref.
SUBTASK 21-22-91-010-003-B01).
Install the control board
(01-330) (Ref. SUBTASK
21-22-91-410-003-A01) or (Ref.
SUBTASK 21-22-91-410-003-B01).
Replace the filter board (01-170).
Remove the filter board
(01-170) (Ref. SUBTASK
21-22-91-040-001-A01) or (Ref.
SUBTASK 21-22-91-040-001-B01).
Install the filter board (01-170) (Ref.
SUBTASK 21-22-91-440-001-A01).
21-22-91
Page 1020
Dec 15/06