Honeywell LMB HYPER 120-03 Component Maintenance Manual With Illustrated Parts List page 59

Table of Contents

Advertisement

DEFECT
5. Free Delivery and Operational Tests (Ref. SUBTASK 21-22-91-750-005-A01) (Ref. SUBTASK
21-22-91-750-006-A01) (Ref. SUBTASK 21-22-91-720-001-A01) (Ref. SUBTASK 21-22-91-720-002-A01)
The motor does not
start.
The document reference is online, please check the correspondence between the online documentation and the printed version.
COMPONENT MAINTENANCE MANUAL
POSSIBLE CAUSE
Incorrect connection of the 28 V power
supply.
The adjustment of the detection board
(01-450) is not correct.
The electronic boards are defective.
00001059
Make sure that the motor is supplied
with 28 V.
Make sure that the connectors (01-100)
and (01-130) are correctly connected.
Adjust the position of the detection
board (01-450) (Ref. SUBTASK
21-22-91-820-001-A01).
Replace the power board (01-370).
Remove the power board
(01-370) (Ref. SUBTASK
21-22-91-010-004-A01) or (Ref.
SUBTASK 21-22-91-010-004-B01).
Install the power board (01-370) (Ref.
SUBTASK 21-22-91-410-002-A01).
Replace the control board (01-330).
Remove the control board
(01-330) (Ref. SUBTASK
21-22-91-010-003-A01) or (Ref.
SUBTASK 21-22-91-010-003-B01).
Install the control board
(01-330) (Ref. SUBTASK
21-22-91-410-003-A01) or (Ref.
SUBTASK 21-22-91-410-003-B01).
Replace the filter board (01-170).
Remove the filter board
(01-170) (Ref. SUBTASK
21-22-91-040-001-A01) or (Ref.
SUBTASK 21-22-91-040-001-B01).
Install the filter board (01-170) (Ref.
SUBTASK 21-22-91-440-001-A01).
21-22-91
CORRECTION
Page 1019
Dec 15/06

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

00001059 amdt b00001059 amdt c