(h)
Put the Control S/A (01-290B) in position on the tie-rods (01-440).
(i)
Apply a layer of adhesive material (M38B) on the thread of the three tie-rods (01-440).
(j)
Attach the Control S/A (01-290B) with the three washers (01-310) and the three nuts
(01-300).
SUBTASK 21-22-91-440-001-A01
(7)
Assembly of the Filter S/A (01-160)
(Ref. IPL Fig. 01)
(Ref. Fig. 7005)
(Ref. Fig. 7006)
(a)
Shrink a 50 mm (1.968 in) length of heat shrinkable conduit (01-730) on the ferrite
(01-650) as shown in Fig. 7005.
(b)
Shrink a 13 mm (0.512 in) length of heat shrinkable conduit (01-750) on the ferrite
(01-660).
(c)
Shrink a 13 mm (0.512 in) length of heat shrinkable conduit (01-740) on the ferrite
(01-670).
(d)
Install the ferrite (01-650) on the power cables which go to the connector (01-130).
NOTE: Take care to not install the ferrite (01-650) on electronic components of the board,
(e)
Install the ferrites (01-660) and (01-670) on the filter board (01-170A) as shown in Fig.
7005.
(f)
Install heat shrinkable conduits (01-760) in the ferrites (01-660) and (01-670) to protect
their inner side.
(g)
Bond the three ferrites (01-650), (01-660) and (01-670) with adhesive material (M82B)
(Ref. Fig. 7005).
(h)
Let dry at ambient temperature during twelve hours.
(i)
Shrink a 60 mm (2.362 in) length of heat shrinkable conduit (01-760) on the five wires
which go to the connector (01-100).
(j)
Shrink a 15 mm (0.591 in) length of heat shrinkable conduit (01-760) on the two power
cables which go to the connector (01-130).
Protection of the power cables and wires between the filter board and the power board:
(k)
1
Shrink a 70 mm (2.756 in) length of heat shrinkable conduit (01-760) on the four
wires which come from the power board (01-370).
2
Shrink a 30 mm (1.181 in) length of heat shrinkable conduit (01-760) on the two
power cables which come from the power board (01-370).
3
Push the heat shrinkable conduits (01-730) in the conduit (01-270).
(l)
For PNR 00001059 Amdt B
The document reference is online, please check the correspondence between the online documentation and the printed version.
COMPONENT MAINTENANCE MANUAL
00001059
but make sure to let enough free space for the installation of the cover (01-040).
21-22-91
Page 7014
Dec 15/06