(c)
Do all the inspections/checks on the cleaned parts.
(8)
Repair
This Page Block contains the full repair procedures and specifications which are necessary
to repair a worn or damaged part. As specified in the INSPECTION/CHECK section, you
must reject the defective parts if the document does not give a repair procedure. Replace
the defective parts with new parts.
(9)
Assembly
(a)
This Page Block gives step-by-step assembly instructions in a correct sequence, which
refer to the figure item numbers from the IPL illustration(s), if applicable.
(b)
Put the component on a clean workbench, in a dust-free and moisture-free room. More all
the parts carefully, and prevent corrosion and impact damage to them.
(c)
Be sure to remove the storage protection coating from all the new parts before assembly.
Clean the new part if necessary.
(10)
Fits and Clearances
(a)
This Page Block gives a table and some figures which gives the fits and clearances data
and the torque values for assembly. It also gives the permitted wear for in-service /
service, and the manufacturer's design wear-tolerances.
(b)
Fits and Clearances Table
1
The identifiers in column (1) show the location of the clearance or the dimension that
you must measure..
2
The identifiers in column (2) identify the parts in the IPL (Figure + Item number).
3
Column (3) gives the initial manufacturing dimensions and clearances.
4
In-service Wear Limits (Columns 4).
a
b
(c)
Torque Values
1
All torque values in this manual are shown in the Table of Tightening Torques. The
parts are identified by the figure number and the item number of the IPL.
(d)
Spring Data
1
The technical data for all springs used in the unit are shown in the Table of Spring
Data. The parts are identified by the figure number and the item number of the IPL.
The document reference is online, please check the correspondence between the online documentation and the printed version.
COMPONENT MAINTENANCE MANUAL
00001059
The maximum limits are the maximum wear limits. If the part is in these limits
then it is serviceable.
If the parts have more wear than the specified limits, you must repair or replace
them.
21-22-91
INTRO
Page 4