Bosch Rexroth IndraDrive MPH-02 Functional Description page 102

Firmware for drive controllers
Table of Contents

Advertisement

4-48
Master Communication
Basic Setting
Control word/status word
Res
G/F
L
M → S
0
1
1
S → M
0
0
1
Non-Fragmented Reading
Control word/status word
Res
G/F
0
1
M → S
S → M
0
0
Without considering a fragmentation or an error, the parameter channel
when writing a parameter is made up of:
Control word
M → S
Status word
S → M
Without considering a fragmentation, the parameter channel when
reading a parameter is made up of:
Control word
M → S
Status word
S → M
The control unit defines the basic setting and the drive responds with the
identifier (2 bytes) of the supported parameter channel format; in this
case with 01V00.
T
FL
GL
0/1
0
0
0/1
2
2
Fig. 4-25:
Basic setting for parameter channel
The control unit reads the operating data of parameter S-0-0057. It is a
double word, fragmentation therefore is not necessary.
The value is 100.
Parameter mapping:
• index
= 2039h
• sub-index
= 7h
L
T
FL
GL
1
1/0
4
4
1
1/0
4
4
Fig. 4-26:
Non-fragmented reading
Index
2 bytes
2 bytes
2 bytes
Index
2 bytes
2 bytes
2 bytes
User data
B2
B3
B4
B5
-
-
-
-
01h
00h
-
-
User data
B2
B3
B4
B5
20h
39h
00h
07h
00h
00h
00h
64h
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
MPH-02, MPB-02, MPD-02
Sub-index
Data
2 bytes
max. 80
bytes
Sub-index
2 bytes
Data
max. 80 bytes
B6
B7
B8
B9
-
-
-
-
-
-
-
-
B6
B7
B8
B9
-
-
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth indradrive mpb-02Rexroth indradrive mpd-02

Table of Contents