To Connect Chassis-To-Chassis Icim In And Icim Out Ports - Cisco Prisma II HD-LRMW Installation And Operation Manual

1.2 ghz high density long reach multiwave and hybrid modulation qam transmitters
Table of Contents

Advertisement

Chapter 2
Module Installation
part number for a 6-foot DB9 Female to DB9 Male serial extension cable. The
connectors are a serial 9-pin D-shell (EIA 574/232).

To Connect Chassis-to-Chassis ICIM IN and ICIM OUT Ports

Connect the serial extension cable from the ICIM OUT of the chassis
1
containing the ICIM to the ICIM IN connector of the second chassis.
Connect a serial extension cable from the ICIM OUT of the second chassis
2
to the ICIM IN of the third chassis.
Continue this daisy-chain connection until all chassis are connected.
3
Connect an ICIM OUT terminator, part number 4013014, to the ICIM
4
OUT connector on the last chassis in the daisy-chain connection. The
ICIM OUT terminator ships with the ICIM.
Important:
All chassis connected in the daisy-chain must be powered and have a fan tray
¾
installed. A chassis connected in the daisy-chain that is not powered or has no
fan tray installed will cause faulty operation of the ICIM.
All chassis connected in this daisy-chain must have a unique chassis ID number.
¾
If the ICIM OUT terminator that ships with the ICIM is not installed on the last
¾
chassis of a daisy-chain connection, faulty communication with the ICIM may
occur.