Potential Sensor/Potential Control Pcb; Removing The Potential Sensor/Potential Control Pcb - Canon Image Reader-A1 iR5000i Service Manual

Photocopy machines
Hide thumbs Also See for Image Reader-A1 iR5000i:
Table of Contents

Advertisement

7.4 Potential Sensor/Potential Control PCB

7.4.1 Removing the Potential Sensor/Potential Control PCB

Be sure to replace the potential
sensor and the potential control
PCB at the same time.
1) Open the front cover, and slide out the
hopper unit.
2) Remove the developing assembly and
the primary charging cooling fan.
(See p.7-36P)
3) Disconnect the connector [1], and re-
move the screw [2]; then, detach the po-
tential sensor assembly [3].
4) Remove the three screws [4], and detach
the front door switch cover [5].
5) Free the cable [6] from the cable guide.
6) Remove the six screws [7], and detach
the door switch assembly [8].
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 4 IMAGE FORMATION SYSTEM
[3]
F04-704-01
[5]
F04-704-02
[8]
[7]
F04-704-03
[1]
[2]
[4]
[6]
[7]
4-57 P