LED Description of PROFIBUS-DP
LED status represents the status of the fieldbus board.
LED status
ONLINE GRN
OFF
Offline
Online
ON
Data exchangeable
−
1 Hz blinking
−
2 Hz blinking
−
4 Hz blinking
Board Installation of PROFIBUS-DP
Set the node address of the device using the address configuration switch of the
PROFIBUS-DP board. Set network termination ON or OFF with the terminator switch.
(1) Set the node address of the PROFIBUS-DP board using the address configuration
NOTE
(2) Turn network termination ON or OFF using the terminator switch.
Wiring (PROFIBUS-DP)
PROFIBUS-DP connector is standard D-sub 9 pins connector.
Terminal name for each pin
Terminal No
Case
1
2
3
4
5
6
7
8
9
Prepare the cable for PROFIBUS-DP sold in the market as a communication cable.
NOTE
Install terminating resistors at both ends of the network.
A terminating resistor is installed in the PROFIBUS-DP board. Turn the terminating
resistor ON or OFF using the terminator switch on the front panel.
RC180 Rev.17
OFFLINE RED
Online
Offline
Data unexchangeable
−
−
−
switch. Make sure that the node address is different from the other devices in the
network. Switch on the "×10" side for tens digit address configuration. Switch
on the "×1" side for units digit address configuration.
Generally, a node address from 0 to 125 is available for the PROFIBUS-DP device,
however, this Controller supports node addresses from 0 to 99.
Generally, node addresses are
recommended to be configured
as shown in the table.
Terminal Name
Shield
Not used
Not used
B line
RTS
GND BUS
+5V BUS
Not used
A line
Not used
Setup & Operation 12. Option Units
ERROR RED
Normal operation
−
Initialization error
(Mismatch with network configuration)
Initialization error
(Mismatch with user parameter)
Initialization error
(Module initialization error)
Node address
0
Service unit such as PG/PC
1
Operation panel such as HMI
2
Master station
3-99 (-125)
DP slave station
Device Name
87