Fuse - Epson RC180 Manual

Robot controller
Hide thumbs Also See for RC180:
Table of Contents

Advertisement

6.6 Fuse

NOTE
The fuse is not used for RC180-UL.
Fuse
(1) Turn OFF the Controller and unplug the power connector.
Remove
(2) Remove the Option Unit when it is mounted.
(3) Remove the fan unit
(4) Remove the Motor Drive Module.
(5) Remove four screws on the intermediate
(6) Remove the FG mounting screws
NOTE
■ Before disconnecting the DPB cable connector, always make sure that the power
supply of the Controller is unplugged.
power supply is connected is extremely hazardous and may result in electric
WARNING
shock and/or cause serious safety problems.
RC180 Rev.17
Maintenance 6. Maintenance Parts Replacement Procedures
Refer : Maintenance 6.7.2 Remove Option Unit 1
Maintenance 6.7.5 Remove Option Unit 1, 2
Refer : Maintenance 6.1.2 Replacing Fan Unit
Refer : Maintenance 6.3.2 Replacing Motor Driver (Axis 1 to4)
plate as shown.
(G, RS: 2 screws/ C3, S5: 3 screws)
and remove the plate.
Be sure to remove the intermediate plate
slowly.
The cables are connected to the main
chassis.
Intermediate
G, RS
FG Mounting Screw
(2 screws)
C3, S5
(3 screws)
Intermediate
Plate
Performing this procedure while the
Plate
159