Maintenance 8. Trouble Shooting
No.
Message
Cannot calculate the specified value
2246
using the Tan function.
Specified array subscript is less than ' 0
2247
'.
Array failure. Redim can only be
2248
executed for an array variable.
Array failure. Cannot specify Preserve
2249
for other than a single dimension array.
Array failure. Failed to calculate the
2250
size of the variable area.
Cannot allocate enough memory for
2251
Redim statement.
Cannot allocate enough memory for
2252
ByRef.
Cannot
compare
2253
values.
Specified data is beyond the array
2254
bounds. Cannot refer or update beyond
the array bounds.
Variable
overflow
2255
Specified variable is out of value
range.
Specified array subscript is beyond the
2256
maximum allowed range.
Task number is out of the available
2260
range.
2261
Specified task number does not exist.
Robot number is out of the available
2262
range.
Output number is out of the available
2263
range. The Port No. or the Device No.
is out of the available range.
Command argument is out of the
available range. Check the validation.
2264
Added data 1: Passed value. Added
data 2: argument order.
Joint number is out of the available
2265
range.
2266
Wait time is out of available range.
Timer number is out of available
2267
range.
2268
Trap number is out of available range.
190
Check the specified value. Review the
program.
Check the specified value. Review the
program.
You attempted to redimension the
variable that is not array. Rebuild the
project.
Other than a single dimension array was
specified
Rebuild the project.
Rebuild the project.
Reduce the number of subscripts to be
specified for Redim.
modestly.
Reduce the number of array's subscripts
to be seen by ByRef.
Check whether the string type and the
characters
with
numeric data type are not compared.
Review the program.
Check the number of array's subscripts
and data. Review the program.
or
underflow.
The value that exceeds the range of
Double type is specified.
program.
Reduce the number of subscripts to be
specified. For available subscripts, see
the online help.
For available task number, see the online
help. Review the program.
Review the program.
The available Robot number is 1.
Review the program.
For available output number, see the
online help. Review the program.
For available range of argument, see the
online help. Review the program.
Available Joint number is from 1 to 6.
Review the program.
Available wait time is from 0 to
2147483. Review the program.
Available timer number is from 0 to 15.
Review the program.
Available trap number is from 1 to 4.
Review the program.
Remedy
as
Preserve
for
Redim.
Perform Redim
Review the
Note 1
Note 2
The
specified
value
The
specified
value
The number
The number of
of data to be
array subscripts
referred or
updated
The
specified
task number
The
specified
task number
The
specified
robot number
The
specified
output number
The
specified
What number
value
argument?
The
specified
joint number
The
specified
wait time
The
specified
timer number
The
specified
trap number