Setup & Operation 12. Option Units
PROFINET Appearance
LED Description of PROFINET
LED status represents the status of the fieldbus board.
LED status
Power OFF or
OFF
Device is being initialized
ON
Normal operation
Blinking
Blinking once Evaluating
Structure Error
Blinking
once
Blinking
No station name has been set or
3 times
No IP address has been set
Blinking
Internal error
4 times
Board Configuration (PROFINET)
PROFINET settings such as the communication setting are all configured by the
development software (EPSON RC+ 5.0). You don't need to configure anything about
PROFINET board.
104
Status Display LED
RJ45 Connector
MS
-
- Too many (Sub) Modules
- I/O size set by IO controller
is too large.
- Structure mismatched
(No module, wrong module)
MS LED
CS LED
LNK/ACT LED : Link status /
Refer to the following table for functions
of LEDs.
CS
Offline
Offline
IO controller is in RUN
-
Offline /
IO controller is in STOP
-
-
-
: Module status display
: IO Controller
connection status
display
Communication packet
reception or
transmission status
display
LNK/ACT
No link or
Power OFF
Linking
Receiving/transmitting
communication packet
-
-
-
-
RC180 Rev.17