Setup & Operation 12. Option Units
(6) Click the "+" displayed on the left of [Input / Output] and select the [EtherNet/IP].
(7) Set each item to the specific value to connect the Ethernet network.
(8) When the configuration is completed, click the <Apply> button to apply the setting.
(9) Click the <Close> button.
NOTE
When Address Configuration is set to "DHCP/BOOTP/ARP", the Controller waits for
DHCP/BOOTP/ARP sever response for 30 seconds at Controller startup.
DHCP/BOOTP/ARP does not response within a time, the Controller stops the request to
the DHCP/BOOTP/ARP server and waits ARP.
Operation
For details, refer to 12.3.9 Operation.
Electronic Information File (EDS file)
An EDS file is supplied for EtherNet/IP network configuration. The file is located in the
following folder in the Manual Update CD that is attached to the Robot Controller.
102
(7)
For information about the setting values, contact your network administrator.
Address Configuration is set to "DHCP/BOOTP/ARP" at shipment.
\EpsonRC50\Fieldbus\EtherNet/IP