Epson RC180 Manual page 197

Robot controller
Hide thumbs Also See for RC180:
Table of Contents

Advertisement

No.
Message
Exceed the global variable area.
2059
Cannot assign the Global variable area.
SRAM failure.
2070
SRAM is not mapped.
SRAM failure. Cannot delete when
2071
Global Preserve variable is in use.
Exceed the backup variable area.
2072
Cannot assign the Global Preserve
variable area.
SRAM failure.
2073
Failed to clear the Global Preserve
variable area.
SRAM failure.
2074
to clean up the Global Preserve
variable save area.
Initialization failure.
2100
Failed to open the initialization file.
Initialization failure.
2101
Duplicated initialization.
Initialization failure.
2102
Failed to initialize MNG.
Initialization failure.
2103
Failed to create an event.
Initialization failure.
2104
Failed to setup a priority.
Initialization failure.
2105
Failed to setup the stack size.
Initialization failure.
2106
Failed to setup an interrupt process.
Initialization failure.
2107
Failed to start an interrupt process.
Initialization failure.
2108
Failed to stop an interrupt process.
Initialization failure.
2109
Failed to terminate MNG.
Initialization failure.
2110
Failed to allocate memory.
Initialization failure.
2111
Failed to initialize motion.
Initialization failure.
2112
Failed to terminate motion.
Initialization failure.
2113
Failed to map SRAM.
Initialization failure.
2114
Failed to register SRAM.
Initialization failure. Fieldbus board is
2115
beyond the maximum count.
Initialization failure.
2116
Failed to initialize fieldbus.
Initialization failure.
2117
Failed to terminate fieldbus.
RC180 Rev.17
Remedy
Reduce the number of Global variables
to be used.
Replace the CPU board.
Perform the same processing after a
while. Rebuild the project.
Reduce the number of Global Preserve
variables to be used.
Rebuild the project.
Reboot the controller.
Restore the controller configuration.
Reboot the controller.
Reboot the controller.
Reboot the controller.
Reboot the controller.
Reboot the controller.
Reboot the controller.
Reboot the controller.
Reboot the controller.
Reboot the controller.
Reboot the controller.
Restore the controller configuration.
Reboot the controller.
Replace the CPU board.
Replace the CPU board.
Check the number of fieldbus boards.
Reboot the controller.
Check the fieldbus board.
Replace the fieldbus board.
Reboot the controller.
Maintenance 8. Trouble Shooting
Note 1
Maximum size
Note 2
The size you
attempted
to
use
185

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents