Entering Xy Tip Calibration Values Manually (Firmware Version 9.1 Or Newer) - HP Designjet 3D Service Manual

Hide thumbs Also See for Designjet 3D:
Table of Contents

Advertisement

Figure 320: Example XY Tip Calibration Part.
This example requires an adjustment of X = + 2 mils, Y = - 4 mils
NOTE: Unusual circumstances may require that the XY Tip
Calibration values be entered manually. To change these values,
see
"Entering XY Tip Calibration values manually (Firmware version
9.1 or newer)" on page 341.

Entering XY Tip Calibration values manually (Firmware version 9.1 or newer)

XY Tip is the XY distance from model tip to the support tip. To move support
roads to the right (+X), apply a positive offset. To move support roads to
the back (+Y), apply a positive offset. If the calibration model is too far off
to read, these values may be set to default as a starting point for
calibration. The default values are X: 0.780" and Y: 0.000".
1. While the printer is at Idle, enter standby mode by pressing the
Standby... button.
2. Enter the Service Calibration menu by pressing the following button
sequence on the display panel: 3,2,3,3,1. See
Figure 321.
-341